Pavilion
90.00° | 08-40-56-88 | ||
---|---|---|---|
90.00° | 04-44-52-92 | ||
90.00° | 96-48 | ||
1 | 42.00° | 96-48 | Locate girdle on preform. |
2 | 42.00° | 02-46-50-94 | Meet P1-G1-G2 |
4 | 49.00° | 04-44-52-92 | Meet P1-P2-P3-G1-G2 |
3 | 41.00° | 01-47-49-95 | Meet P1-P2-G1-G2 |
5 | 51.46° | 08-40-56-88 | Connect P2-P4-P4-P2 and P4-G2-G3 |
Crown
A | 35.00° | 96-48 | Fix girdle width. Match pavilion. |
---|---|---|---|
B | 35.00° | 04-44-52-92 | Level girdle |
C | 33.18° | 08-40-56-88 | Level girdle |
D | 31.16° | 02-46-50-94 | Meet A-B-G1-G2 |
E | 31.30° | 06-42-54-90 | |
F | 20.00° | 02-46-50-94 | Meet D-A-D |
G | 20.00° | 06-42-54-90 | Meet D-B-E-F |
T | 0.00° | Table |